An MCB protects a circuit against excessive current. An RCD detects current taking an unintended return path. An RCBO does both jobs in one device. When comparing consumer unit quotes, ask one more question after identifying the devices: if a fault develops on the garden sockets, which other parts of my home could go off with them? The answer depends on how the electrician divides the installation.
Imagine coming home to a defrosting freezer after rain entered a garden accessory. In one property the garden and kitchen have separate circuit breakers but share residual current protection. In another they have individual RCBOs. The two boards can look similar with the lids closed, yet the scope of that interruption can be quite different. Here is how to read a proposal and understand what the labels mean for the people using the building.

What an MCB protects
MCB stands for miniature circuit breaker. Think of a portable heater and other equipment drawing more current through a circuit than it is designed to carry. A sustained overload can cause an appropriately selected MCB to disconnect. A short circuit can produce a much larger current, requiring a much faster response. Both are examples of overcurrent, although they arise in different ways.
A rating such as 32 A describes the breaker’s rated current. It does not mean that a circuit can supply any collection of equipment indefinitely, or that the device trips the instant current reaches 32.1 A. Its operating characteristic relates current to time. The electrician selects protection alongside the conductors, installation conditions and measured or calculated fault conditions. A bigger number on the handle is no remedy for repeated tripping.
An MCB may disconnect some faults to earth when sufficient current flows. It cannot provide the sensitive residual current protection associated with a 30 mA RCD. If a quotation simply says “breakers included”, ask what kind of protection each circuit receives. The price of a board containing several MCBs makes little sense until you know whether there are also shared RCDs or individual combined devices.
What an RCD detects
On a typical single-phase circuit, current goes out through the line conductor and returns through the neutral. A residual current device monitors the balance. If enough current returns by another route, the device operates according to its characteristics. That can reduce the risk of serious injury in certain shock situations. It cannot prevent every electric shock or make exposed wiring safe to touch.
RCD is the family name. The device often called “the RCD” on an older split-load board is an RCCB, a residual current circuit breaker without integral overcurrent protection. Several MCBs can sit downstream of one RCCB. Each MCB looks after overcurrent on its own circuit while the RCCB watches the combined current balance for its group. The IET explains the distinction and the ratings on an RCCB.
For example, an RCCB labelled 63 A and 30 mA has two figures describing different things. The ampere marking concerns the current it is rated to carry. The milliampere marking concerns residual current operation. It would be a mistake to treat the 63 A marking as evidence that the RCCB can trip on overload at that value. The design needs separate consideration of overcurrent protection.
What an RCBO adds
An RCBO is a residual current operated circuit breaker with integral overcurrent protection. A common domestic arrangement assigns one to each final circuit. If a dishwasher fault operates the kitchen socket RCBO, other independently protected final circuits can remain in service. Everything on the affected kitchen circuit may still lose power. The device cannot distinguish a dishwasher socket from a freezer socket on the same cable run.
A trip at an RCBO gives the investigator a starting point. The cause might involve excess current, an imbalance or connected equipment. Some products have indicators that help identify why they operated. Those features vary. A photo of the precise model and any visible indication is more useful than a guess based on the colour of a window. Keep the front cover in place when taking a photograph.
Individual protection also helps with scheduling maintenance. Suppose the electrician needs to work on an outdoor circuit while someone works from home. Knowing which circuit supplies the router and which serves the garden helps the household plan. The electrician will establish safe isolation for the work. Labels alone never establish that conductors are dead, and other work on the board may still require a wider shutdown.
Read a device marking without confusing the letters
A manufacturer’s example makes the lettering easier to follow. Hager lists an RCBO with a B curve, a 32 A current rating, 30 mA residual current sensitivity, Type A residual current detection and a 6 kA breaking capacity. Each item describes a separate feature. The adjacent letters B and A are describing different behaviours of the same device. See Hager’s technical data for the ADA932U.
The B beside the current rating identifies an overcurrent tripping characteristic. Type A identifies the kinds of residual current waveform the device is designed to detect. The breaking capacity concerns interrupting a short circuit under defined conditions. None of those figures is the number of appliances you can plug into a room. The designer considers the intended load and the installation when selecting the device.
This is especially relevant where quotes use the word “type” without explaining it. Ask for a manufacturer and part reference for the protective devices as well as the enclosure. If the contractor later proposes an alternative, the references allow an informed comparison. Two modules with the same width, similar lettering and matching handles do not thereby form an approved combination with a particular board.

Compare what goes off in each design
Draw three columns headed circuit, equipment and shared protection. One row might read “downstairs sockets, router and lounge, shared RCCB one”. Another might read “garden sockets, pond pump and outside outlet, shared RCCB one”. Seeing the entries together makes the consequence clear. An imbalance on either circuit can interrupt both, even if neither individual MCB has operated.
Now repeat the exercise for individual RCBOs. In that layout a garden fault can be confined to the garden circuit, provided no upstream device or other fault also interrupts supply. The router could still stop if it shares a circuit with the faulty equipment. Ask the contractor to account for actual circuit boundaries. Installing individual devices on existing circuits does not divide one large circuit into smaller ones.
Consider the effect of losing lighting on stairs, refrigeration in a garage or heating controls during cold weather. Explain which items matter to the occupants and when. An electrician designing circuit division needs to consider both inconvenience and the consequences of loss of supply. The IET discusses division of installations and unwanted tripping, including how leakage from several connected loads can affect shared protection.
What to ask before accepting a replacement quote
Ask for the number of existing circuits being transferred, how unidentified circuits will be traced and what preliminary checks the price includes. A garage supply feeding another board may appear as a single entry on the house schedule. Its downstream circuits need to be understood as well. A quote for ten outgoing ways does not automatically cover every protective device anywhere on the property.
Agree what happens if testing reveals a wiring fault. A new device may expose a problem that the previous arrangement did not reveal. Tell the electrician about earlier tripping, recent kitchen alterations and equipment that stays connected overnight. Ask how findings will be recorded, whether remedial work is included and how you will approve additional costs before the work proceeds.
At handover, request a legible circuit schedule and the electrical installation certificate with its schedules. Ask the installer to point out which controls are intended for routine user operation and demonstrate the relevant test buttons. Keep the manufacturer’s instructions with the paperwork. If the board is inside a cupboard, make sure ordinary storage will leave access for reading the labels and carrying out the recommended user checks.
Two quotes for a house with a detached garage
Imagine receiving two prices for a three-bedroom house. Both descriptions promise a new consumer unit with individual RCBOs. The first contractor has counted the garage feed among eight existing circuits. The second has included replacing the small board inside the garage as a separate item. Someone comparing only the headline prices could easily assume the cheaper contractor has priced the same work.
Bring both contractors back to the same drawing. Identify the device supplying the garage cable, the equipment inside the garage and where its lights and sockets are controlled. Ask which equipment each offer retains, which it replaces and whether the proposed protection has been considered together with anything downstream. The answer may justify the difference in price or reveal that the extra item needs a closer inspection before a decision.
Next consider the useful outcome for the family. If the garage freezer and garden outlet share one final circuit, moving that circuit onto its own RCBO in the garage still leaves the freezer vulnerable to an interruption on that outlet. Dividing those loads would involve different work. Ask for that option to be priced separately if it matters more to you than changing the enclosure finish or adding empty ways.
Finally agree what the circuit schedule will call the two boards. “Garage” on the house schedule identifies a destination. “Garage sockets and freezer” on the downstream schedule identifies a final circuit. These small distinctions help the next electrician trace the arrangement, and they help a neighbour checking the house report the correct location if something goes off while you are away.
For a home office in that garage, add the internet equipment to the drawing. A router in the house and a network switch in the garage depend on two circuit supplies. Either interruption could take the office offline.
Frequently asked questions
Can an MCB stay on while several circuits lose power?
Yes. If several circuit breakers are supplied through one RCCB, that shared device can disconnect their supply while their MCB handles remain in the on position. Note which lights and appliances lost power and which device appears to have operated. An electrician can use the circuit schedule and test results to establish what happened. Leave a repeatedly tripping device alone.
Does a test button mean the device is an RCBO?
A test button is found on different devices with residual current functions, including RCCBs and RCBOs. Look for a model number on the visible face or the installation schedule. The manufacturer’s datasheet can then identify the product. Avoid opening the board to read anything concealed. A wider device with a test button may serve several circuits.
Will an RCBO fix a circuit that keeps tripping?
First establish why the protection is operating. Individual devices can reduce the number of unrelated circuits affected by a fault, but an appliance leaking current or damaged wiring still needs investigation. Record the time, weather and equipment in use when the problem occurs naturally. Our electrical fault finding service is the appropriate route for a continuing trip.
How often should I use the RCD test button?
Electrical Safety First advises testing domestic RCDs at least every six months. Follow the device instructions and any shorter interval specified for your installation. Plan for the connected circuits to lose power during the test, particularly where essential equipment is supplied. If the device fails its user test, contact an electrician promptly. Read the domestic RCD advice from Electrical Safety First.
What should I send for a consumer unit quote in Enfield?
Send a clear photograph of the closed-front board showing the accessible labels, the current circuit schedule and any recent electrical report. Identify outbuildings and equipment for which an interruption would cause particular difficulty. Mention planned alterations so they can be considered in the design. Visit our consumer unit and fuse box replacement page or contact Intela Electricals to discuss the property.